6. Installer Requirements

scope

6.1 Introduction

must : Requirements that are marked as must are considered mandatory and must exist in the reference implementation and implemented by installer. The same applies to must not .

may : Requirements that are marked as may are considered optional. The same applies to may not .

6.2 Installer requirements

6.2.1 General

The Descriptor File defines the unique configuration required by installer in a common schema. It would specialize the installer type per user’s implementation requirements. It would be validated at the very beginning of the deployment. It’s the installer’s responsibility to translate the descriptor file to adapt with its own configuration. Thanks to the descriptor file, the NFVi infrastructure deployment could be completed in one step run.

Ref # sub-category Description
req.gen.ins.01 Installer Installer may accept a descriptor file to finish deployment.
req.gen.ins.02 Installer Installer implementation must validate the descriptor file with schema.
req.gen.ins.03 Installer Any existing installer implementation may need adaption for the descriptor file.
req.gen.ins.04 Installer Installer may support reporting the deployment progress status.
req.gen.des.01 Descriptor Descriptor file must include hardware resource configuration, software configuration.
req.gen.des.02 Descriptor Descriptor file may include additional extending configuration.

Table 6-2-1: Installer requirements

6.2.2 Additional

Depends xxx.

6.3 Descriptor file definition specification

There must be a Descriptor File definition, which used by installer as input of necessary configuration. Mandatory and optional definition shall be defined, there’s no restrictions on how to use it, there could be multiple ways to implement PDF, the implementation will be in next section.

6.3.1 Resource Pool information

This table is the description of the resource pool, it contains only 2 parameters: name and type of the resource pool.

A resource pool maps to only one instance of below parameters.

Field # type mandatory Instruction
RES_POOL_NAME String Yes This is the unique name of the resource pool, could be refered by other parameters
RES_POOL_TYPE String No User defined value to identify different hardware or software configuration requirements.

Table 6-3-1: Resource Pool Information.

6.3.2 Global Settings

The Global settings are provided by the user, contains data like like IP_Type, VLAN_Type, etc.

A resource pool maps to only one instance of below parameters.

Field # type mandatory Instruction
IP_TYPE String Yes IPV4 or IPV6
NETWORK_TYPE String Yes VLAN or VXLAN
TIMEZONE String Yes The timezone where VIM deployed, like UTC+8
STORAGE_TYPE String Yes The Storage type, for example "ceph"
HUGEPAGE_ENABLE String Yes TRUE or FALSE
HUGEPAGE_SIZE String Yes The storage size that hypervisor set for VM, for example "1GB"
QINQ_ENABLE String Yes TRUE or FALSE
HYPERVISOR_CORES String Yes number of vCPU (CPU cores or hardware threads) assigned to the Hypervisor
EXTERNAL_NTP_SERVER_IP List Yes IP list of NTP server, seperated by comma, for example: primariy_IP;second_IP

Table 6-3-2: Global Settings

6.3.3 Parameters for network virtualization

MTU(Maximum Transmission Unit) configuration in switch is different depends on the which network plane it belongs to, this is usually standard value that defined by user.

3 instances of the parameters are expected(Manage Storage and Service), they may have different MTU requirement.

Field # type mandatory Instruction
SWITCH_TYPE String Yes There should be 3 type of switch based on the network plane: Manage, Storage, and User Services
MTU String Yes Maximum transmission unit

Table 6-3-3: Network Virtualization parameter .

6.3.4 server information

Server information should be provided for installer, including full detail info. for each server, NIC mapping etc.

6.3.4.1 server information

A table describing information for each server in the resource pool shall be provided

Multiple instances are expected, one instance of all the parameters for each server.

Field # type mandatory Instruction
NAME String Yes Server name should be aligned with naming rule, this is the unique ID for each device to be referred for identify device
VENDOR String No Vendor of device
SKU String Yes The SKU of device, can be referred by other table NIC connection table, to identify slot-port mapping for device
MODEL String Yes This is the model for different service type, this value is defined from design document of resource pool, example NC1, NC1-S
SN String Yes Serial Number, each server has a unique SN
RES_POOL String Yes Resource pool name
RACK String Yes rack name where device located
POS String Yes the position of device in rack, like 2-3U,4-5U
BMC_IP String Yes
BMC_GATEWAY String Yes
BMC_MASK String Yes
BMC_SUBNET String Yes
BMC_USR String Yes BMC user
BMC_PWD String Yes BMC password, Instead of clear-text password, password encryption is recommended for security consideration
INTERNAL_IP String Yes It is an internal IP configured and used by hardware integration tools, it will be removed after hardware integration verification
INTERNAL_GATEWAY String Yes
INTERNAL_MASK String Yes
GROUP_NAME String Yes Usage of server, Manage or Storage or Service
BMC_PRE_CONFIGURED String Yes YES or NO
HW_REGION String No Hardware region divided by room or area, this is need when pod needs to build on more than one lab, For example: Lab01 or Lab02
MODULE_NAME String Yes hardware model that divided within each region, Like "Model 3 in Region A", usually contains certain number of racks

Table 6-3-4-1: Server Information.

6.3.4.2 server NIC information

This table is describing the slot and port mapping for NICs in each type of server. Port BDF( Bus:Device.Function (BDF) Notation ) information is also needed for each port, it will be used to identify the logical port name after OS is installed.
Multiple entries per server type are expected for describing all NIC slots, 1 entry for each port. Information for all server types in pool should be included.

Field # type mandatory Instruction
VENDOR String Yes Vendor of server
SKU String Yes SKU of server
SERVICE MODEL String Yes server service type defined by provider/user, same definition as in above table, example: NC1 or NC2
SLOT String Yes Slot number in server for each NIC, for example, PCIeSlot2
NETWORK_PLANE String Yes Network plane for each nic, Manage or Storage or Service
PORT List Yes Ports number for the above NIC, for example: 1_1 or 1_2, 2 ports for one NIC, so 2 entries are needed for same slot
PORT_BDF String Yes Port BDF value for above port

Table 6-3-4-2: Server NIC Information.

6.3.5 Network Device information

This table describes each network device, it can be used for network configuration and verification.

Multiple instances are expected, one instance for each network device.

Field # type mandatory Instruction
NAME String Yes Name of network device
VENDOR String Yes Vendor name for network device
SKU String Yes SKU
MODEL String Yes Type of switch, like Access Switch or Aggregation Switch
SN String Yes Serial number
HW_RES_POOL String Yes Resource pool name for hardware
RACK String Yes rack number where switch is placed
POS String Yes position in rack
BMC_IP String Yes
BMC_GATEWAY String Yes
BMC_MASK String Yes
BMC_USR String Yes BMC login user
BMC_PWD String Yes password for BMC login user. Instead of clear-text password, password encryption is recommended for security consideration
ENABLE_PWD String Yes Enable password. Instead of clear-text password, password encryption is recommended for security consideration
GROUP_NAME String Yes Manage or storage or service
HW_REGION String Yes Hardware region
MODULE_NAME String Yes Hardware module which is devided by location, like area A module 1

Table 6-3-5: Network device information.

6.3.6 Port mapping information

Wiremap defines the port mapping between server/switch and switch for each line, we will need this information to trace the connected server and port, so we can extrapolate the required network configuration for the port.

Multiple instances are expected, one instance for each physical cable.

Field # type mandatory Instruction
NAME String Yes Name of network device
LOCAL_RACK String Yes the rack info for local device
LOCAL_NAME String Yes local device name, LOCAL_NAME must reference either "Network Device Name" from table 6.3.5
LOCAL_TYPE String Yes Local device type, switch or server
LOCAL_PORT String Yes connected port in local device
REMOTE_RACK String Yes
REMOTE_NAME String Yes connected remote device name, REMOTE_NAME must reference either "Network Device Name" from table 6.3.5 or "Server Name" from table 6.3.4.1
REMOTE_TYPE String Yes remote device type, it can be switch or server
REMOTE_PORT String Yes connected port in remote device. When describing port for remote servers, we use port number like 1_1, or 1_2, instead of PCIeslot number, because the server NIC mapping is already defined in 6.3.4.2
LINE_TYPE String Yes Line type to describe local device type and remote device type, how each line is connected. For example "S-SRV-C_S-TOR" means this line is connecting a service server in compute module to service TOR, and another example "ST-SRV-S_M-TOR" means storage server connecting to a manage TOR in storage module. The line type can be customized defined, as long as it's unified in end user.

Table 6-3-6: Port mapping information.

6.3.7 Network planning information

Network planning information for the resource pool of each node needs to be defined which should include VLAN ID an allocated IP range.

Multiple instances are expected, one instance for each network plane.

Field # type mandatory Instruction
APPLICATION_LAYER String Yes VIM or storage
DOMAIN String Yes name of VIM/storage software product
VENDOR_NETWORK_PLANE String Yes network plane designed/needed by software product
NETWORK_PLANE String Yes corresponding network plane in user view, like Manage, Storage, service
VENDOR String Yes vendor of software product
VLAN_ID List Yes designed VLAN id or id list for each network plane
IP_SEGMENT String Yes assigned IP segments
GATEWAY String Yes gateway IP for each IP range
SWITCH_CONFIG_TYPE String Yes

Table 6-3-7: Network planning information.

6.3.8 TOR(Access switch) VLAN configuration information

Multiple instances are expected, one instance for each TOR.

Field # type mandatory Instruction
DEVICE_NAME String Yes
VENDOR String Yes
DEVICE_MODEL String Yes
DEVICE_SN String Yes
BMC_IP String Yes
SSH_USER String Yes
SSH_PASSWORD String Yes Instead of clear-text password, password encryption is recommended for security consideration
ENABLE_PASSWORD String Yes Instead of clear-text password, password encryption is recommended for security consideration
PORT List Yes group multiple ports with same VLAN configuration, and separate different port group with ";"
VLAN_TYPE List Yes tag or untag
VLAN_ID List Yes group multiple VLAN with same configuration requirements, and separate different VLAN group with ";"
PORT_TYPE List Yes trunk or access or hybrid

Table 6-3-8: TOR VLAN information.

6.3.9 VLAN configuration for Aggregation Switch

Multiple instances are expected, one instance for each Aggregation Switch.

Field # type mandatory Instruction
DEVICE_NAME String Yes
VENDOR String Yes
DEVICE_MODEL String Yes
DEVICE_SN String Yes
BMC_IP String Yes
SSH_USER String Yes
SSH_PASSWORD String Yes Instead of clear-text password, password encryption is recommended for security consideration
ENABLE_PASSWORD String Yes Instead of clear-text password, password encryption is recommended for security consideration
PORT List Yes group a list of ports with same VLAN configuration, and separate different port group with ";"
VLAN_ID List Yes group multiple VLAN with same configuration requirements, and separate different VLAN group with ";"
VLANIF_ADDRESS List Yes Vlanif addresses that need to be configured on Aggregation Switch
NETWORK_MASK List Yes

Table 6-3-9: Aggregation Switch VLAN information.

6.3.10 Host Aggregate information

Servers in the resource pool are usually divided to multiple groups, will use HA(Host Aggregation) to represent host group. One HA could belong to multiple AZ(Availability Zone) It is the definition of each HA in the resource pool. it should contain the server list for each HA, and also the HA meta data.

6.3.10.1 Host HA Mapping

Multiple instances are expected, defines all servers in HA | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | HA_NAME | String | Yes | HA name, which will following naming rules. | | DEVICE_NAME | String | Yes | server name in current HA |

Table 6-3-10-1: Host HA Information.

6.3.10.2 HA metadata

Multiple instances are expected, service, management and DMZ. | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | HA_NAME | String | Yes | | | HA_METADATA | String | Yes | properties for each HA, for example: type=TrustPlane,ovs=C-plane,sriov=false | | AZ_NAME | String | Yes | AZ name that HA belongs to |

Table 6-3-10-2: HA meta Information.

6.3.11 VIM Nodes

There’s a list of servers that was defined as control/management nodes according to resource pool plan

Multiple instances are expected, defines all management servers. | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | DEVICE_NAME | String | Yes | The server name |

Table 6-3-11: VIM Nodes Information.

6.3.12 SDNC Nodes

Multiple instances are expected, defines all SDN controllers | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | DEVICE_NAME | String | Yes | The server name |

Table 6-3-12: SDNC Nodes Information.

6.3.13 Storage cluster information

Definition of storage cluster and storage pool,

6.3.13.1 Storage pool plan

Storage pool name in each storage cluster, and nodes in Storage pool should be defined, so the storage installer will know which nodes are installing.

Multiple instances are expected, each instance defines one storage node | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | STORAGE_CLUSTER_NAME | String | Yes | Storage cluster name, which needs to follow naming rules. | | STORAGE_POOL_NAME | String | Yes | Storage pool name, which needs to follow naming rules. | | DEVICE_NAME | String | Yes | Storage servers in each storage pool |

Table 6-3-13-1: Storage Pool Plan

6.3.13.2 Distribution storage pool info

Storage pool information, defines the management account and network information

Multiple instances are expected, each instance defines one storage pool | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | STORAGE_CLUSTER_NAME | String | Yes | | | NODE_POOL | String | No | | | DISK_POOL_NAME | String | No | | | STORAGE_POOL_NAME | String | Yes | | | HA_NAME_LIST | List| Yes | The corresponding HA lists for current storage pool | | AZ_NAME | String | Yes | The corresponding AZ for current storage pool | | STORAGE_POOL_NODE_CCOUNT | String | Yes | How many nodes for current storage pool | | MAX_QUOTA_CAPACITY | String | Yes | | | STORAGE_POOL_MANAGEMENT_IP | String | Yes | Designed virtural IP for storage pool management | | NETWORK_MASK | String | Yes | | | GATEWAY | String | Yes | | | VIM_USER | String | Yes | VIM credential | | VIM_PASSWORD | String | Yes | Instead of clear-text password, password encryption is recommended for security consideration | | PIM_USER | String | Yes | PIM credential | | PIM_PASSWORD | String | Yes | Instead of clear-text password, password encryption is recommended for security consideration | | STORAGE_CLUSTER_SERVICE_IP | String | Yes | | | STORAGE_CLUSTER_SERVICE_GW | String | Yes | | | STORAGE_CLUSTER_BACKEND_IP | String | Yes | | | STORAGE_CLUSTER_BACKEND_GW | String | Yes | | | BACKUP_POLICY | String | Yes | |

Table 6-3-13-2: Distribution storage pool info.

6.3.14 Software integration information

After VIM and Storage software installation finished, parameters willl be needed in integration process of VIM and Storage, the parameters should be defined in advance.

6.3.14.1 VIM Context

Parameters from VIM vendor for integration.

Only one entry is expected. | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | VENDOR | String | Yes | | | AUTHORIZATION | String | Yes | One-way or Two-way authentication | | VIM_CERTIFICATES_PATH | String | Yes | Full path for certificates that used for integration |

Table 6-3-14-1: VIM context Information.

6.3.14.2 Storage Context

Parameters from storage vendor for integration.

Only one entry is expected. | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | VENDOR | String | Yes | | | AUTHORIZATION | String | Yes | One-way or Two-way authentication | | JOINT_WAY | String | Yes | by ISCSI or client | | DRIVER_FULL_NAME | String | Yes | Full path for storage driver | | CEPH_CONFIG_PATH | String | Yes | Full path for ceph.conf storage | | IS_PIM_JOINT | String | Yes | whether integrate with PIM, usaually “YES” for this value | | STORAGE_SOFTWARE_VERSION | String | Yes | |

Table 6-3-14-2: Storage context Information.

6.3.14.3 Storage Client context

This table defines the parameters for integration with storage client

Multiple entries are expected, one entry for each authorization user. | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | JOINT_WAY | String | Yes | integration method for storage client, for example, RBD | | COMPONENT_TYPE | String | Yes | for example: cinder, glance or nova | | AUTHORIZATION_USER | String | Yes | match with the component type | | KEYRING_FILENAME | String | Yes | Full path for keyring file, this should match the authentication user, |

Table 6-3-14-3: Storage client context.

6.3.15 Device Management information

6.3.15.1 SERVER PIM(Physical Infrastructure Manager) ACCOUNT

This table is not mandatory because not all installer require redfish. It is only requried when servers managed by PIM through redfish, credentials should be the same for same type of device.

Multiple entries are expected, one entry for each server model. | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | VENDOR | String | No | | | SERVER_MODEL | String | No | MODEL for each type of server | | REDFISH_USER | String | No | | | REDFISH_PASSWD | String | No | Instead of clear-text password, password encryption is recommended for security consideration |

Table 6-3-15-1: SERVER PIM ACCOUNT Information.

6.3.15.2 Switch PIM Account

Servers are managed by SNMP, credentials should be the same for same type of device

Multiple entries are expected, one entry for each device model. | Field # | type | mandatory | Instruction | |—-|——————–|—————————-|—————————————————————————————————————————————————————————| | VENDOR | String | Yes | | | DEVICE_MODEL | String | Yes | MODEL for each type of switch | | SNMP_VERSION | String | Yes | v3 by default | | SNMP_USER | String | Yes | | | AUTHENTICATION_METHOD | String | Yes | for example: MD5 or SHA1 | | VERIFICATION_CODE | String | Yes | | | ENCRYPTION_METHOD | String | Yes | | | ENCRYPTION_KEY | String | Yes | |

Table 6-3-15-2: Switch PIM Account.

6.4 Installer prerequisite

6.4.1 Hardware validation

Before the installation, the user has to check if each server meets the deployment requirements:

  • BIOS settings: RAID configuration, PXE boot order and boot mode, disk capacity, CPU, and memory settings,
  • remote management accessibility (for example, IPMI, iLO, BMC),
  • NIC quantity and configuration.

6.4.2 Network configuration

The necessary prerequisite settings must be ready before the deployment, for example:

  • the VLAN must be configured on the switch,
  • the IP address ranges to be used must be allocated.

6.5 PDF implementation

When we use PDF for installer or verification tools, all the required data described in 6.3 should be included. There’s no limitation on how to implement PDF, like the file type of PDF could be csv or json, and also you can adjust the file structure, whichever is more readable to the tools. Taking servers information for example, you can use flat version to include all parameters in 6.3.4 for each device, or you can group servers with same properties like same Vendor, same model, or same usage. You can refer anuket PDF pages for details about how to implement: https://wiki.anuket.io/pages/viewpage.action?pageId=4406598